Vegger - Gruppeoversikt
|
Vegg- gruppe Nr
|
Lab Rw
|
Forventet
|
Brann- klasse
|
Konstruksjon
|
Maks vegghøyde
|
|
|
R’w (1)
|
R’w+ C50-3150
|
c/c 450
|
c/c 600
|
|
Linker
|
dB
|
dB
|
dB
|
EI
|
Forklaring til konstruksjon se under tabellen*
|
dB+
|
dB+
|
|
1.2
|
36
|
31-33
|
-
|
30
|
SE C70 dB+ 1/1 M0
|
3700
|
3600
|

|
|
1.3
|
38
|
33-35
|
-
|
30
|
SE C95 dB+ 1/1 M0
|
4800
|
4600
|
|
1.4
|
38
|
33-35
|
-
|
30
|
SE C120 dB+ 1/1 M0
|
5800
|
5400
|
|
1.6
|
43
|
38-40
|
-
|
30
|
SE C70 dB+ 1/1 M45
|
3700
|
3600
|
|
1.7
|
45
|
40-42
|
-
|
30
|
SE C95 dB+ 1/1 M45
|
4800
|
4600
|
|
1.8
|
45
|
40-42
|
-
|
30
|
SE C120 dB+ 1/1 M45
|
5800
|
5400
|
|
1.21
|
36
|
31-33
|
-
|
60
|
SE C70 dB+ 1F/1F M0
|
3700
|
3600
|
|
1.22
|
38
|
33-35
|
-
|
60
|
SE C95 dB+ 1F/1F M0
|
4800
|
4600
|
|
1.23
|
38
|
33-35
|
-
|
60
|
SE C120 dB+ 1F/1F M0
|
5800
|
5400
|
|
1.24
|
43
|
38-40
|
-
|
60
|
SE C70 dB+ 1F/1F M45
|
3700
|
3600
|
|
1.25
|
45
|
40-42
|
-
|
60
|
SE C95 dB+ 1F/1F M45
|
4800
|
4600
|
|
1.26
|
45
|
40-42
|
-
|
60
|
SE C120 dB+ 1F/1F M45
|
5800
|
5400
|
|
|
|
2.2
|
45
|
40-42
|
37
|
60
|
SE C70 dB+ 2/2 M0
|
4500
|
4200
|

|
|
2.3
|
48
|
43-45
|
40
|
60
|
SE C95 dB+ 2/2 M0
|
5500
|
4900
|
|
2.4
|
48
|
43-45
|
40
|
60
|
SE C120 dB+ 2/2 M0
|
7000
|
6500
|
|
2.6
|
52
|
47-49
|
44
|
60
|
SE C70 dB+ 2/2 M45
|
4500
|
4200
|
|
2.7
|
53
|
48-50
|
45
|
60
|
SE C95 dB+ 2/2 M45
|
5500
|
4900
|
|
2.8
|
53
|
48-50
|
45
|
60
|
SE C120 dB+ 2/2 M45
|
7000
|
6500
|
|
2.9
|
53
|
48-50
|
45
|
60
|
SE C70 dB+ 2/2 M70
|
4500
|
4200
|
|
2.10
|
54
|
49-51
|
46
|
60
|
SE C95 dB+ 2/2 M70
|
5500
|
4900
|
|
2.11
|
54
|
49-51
|
46
|
60
|
SE C120 dB+ 2/2 M70
|
7000
|
6500
|
|
2.12
|
55
|
50-52
|
47
|
60
|
SE C95 dB+ 2/2 M95
|
5500
|
4900
|
|
2.13
|
55
|
50-52
|
47
|
60
|
SE C120 dB+ 2/2 M95
|
7000
|
6500
|
|
|
|
3.1
|
67
|
62-64
|
57
|
60
|
SD C70 dB+ 2/2 M2x45
|
3200
|
2900
|

|
|
3.2
|
68
|
63-65
|
58
|
60
|
SD C95 dB+ 2/2 M2x45
|
3900
|
3600
|
|
3.3
|
68
|
63-65
|
58
|
60
|
SD C120 dB+ 2/2 M2x45
|
4500
|
4200
|
|
3.4
|
67
|
62-64
|
57
|
90
|
SD C70 dB+ 2/2 S2x45
|
3200
|
2900
|
|
3.5
|
68
|
63-65
|
58
|
90
|
SD C95 dB+ 2/2 S2x45
|
3900
|
3600
|
|
3.6
|
68
|
63-65
|
58
|
90
|
SD C120 dB+ 2/2 S2x45
|
4500
|
4200
|
|
|
|
4.1
|
72
|
67-69
|
62
|
60
|
SD C70 dB+ 3/3 M2x70
|
3400
|
3200
|

|
|
4.2
|
72
|
67-69
|
62
|
60
|
SD C95 dB+ 3/3 M2x70
|
4600
|
4400
|
|
4.3
|
72
|
67-69
|
62
|
60
|
SD C120 dB+ 3/3 M2x70
|
5500
|
5200
|
|
4.4
|
72
|
67-69
|
62
|
90
|
SD C70 dB+ 3/3 S2x45
|
3400
|
3200
|
|
4.5
|
72
|
67-69
|
62
|
90
|
SD C95 dB+ 3/3 S2x45
|
4600
|
4400
|
|
4.6
|
72
|
67-69
|
62
|
90
|
SD C120 dB+ 3/3 S2x45
|
5500
|
5200
|
|
|
|
5.1
|
68
|
63-65
|
58
|
120
|
SD C70 dB+ 2/2 S180
|
3200
|
2900
|

|
|
5.2
|
68
|
63-65
|
58
|
120
|
SD C95 dB+ 2/2 S200
|
3900
|
3600
|
|
5.3
|
68
|
63-65
|
58
|
120
|
SD C120 dB+ 2/2 S250
|
4500
|
4200
|
|
|
|
6.1
|
72
|
67-69
|
62
|
120
|
SD C70 dB+ 3/3 S150
|
3400
|
3200
|

|
|
6.2
|
72
|
67-69
|
62
|
120
|
SD C95 dB+ 3/3 S200
|
4600
|
4400
|
|
6.3
|
72
|
67-69
|
62
|
120
|
SD C120 dB+ 3/3 S250
|
5500
|
5200
|
|
|
|
7.2
|
32
|
27-29
|
-
|
30
|
SE C70 dB+ 0/2 M0
|
3400
|
3200
|

|
|
7.3
|
32
|
27-29
|
-
|
30
|
SE C95 dB+ 0/2 M0
|
3900
|
3600
|
|
7.4
|
32
|
27-29
|
-
|
30
|
SE C120 dB+ 0/2 M0
|
4500
|
4200
|
|
7.6
|
40
|
35-37
|
-
|
30
|
SE C70 dB+ 0/2 M45
|
3400
|
3200
|
|
7.7
|
40
|
35-37
|
-
|
30
|
SE C95 dB+ 0/2 M45
|
3900
|
3600
|
|
7.8
|
40
|
35-37
|
-
|
30
|
SE C120 dB+ 0/2 M45
|
4500
|
4200
|
|
|
|
8.2
|
32
|
27-29
|
-
|
60
|
SE C70 dB+ 0/2F M0
|
3400
|
3200
|

|
|
8.3
|
32
|
27-29
|
-
|
60
|
SE C95 dB+ 0/2F M0
|
3900
|
3600
|
|
8.4
|
32
|
27-29
|
-
|
60
|
SE C120 dB+ 0/2F M0
|
4500
|
4200
|
|
8.6
|
40
|
35-37
|
-
|
60
|
SE C70 dB+ 0/2F M45
|
3400
|
3200
|
|
8.7
|
40
|
35-37
|
-
|
60
|
SE C95 dB+ 0/2F M45
|
3900
|
3600
|
|
8.8
|
40
|
35-37
|
-
|
60
|
SE C120 dB+ 0/2F M45
|
4500
|
4200
|
*Forklaring til tabellen:
Eksempel: SE C95 dB+ 2/2 M45
SE = Enklevegg, SD = Dobbelvegg med min 10 mm avstand mellom stenderverkene.
Min 40 mm avstand mellom stenderverkene når stender/skinner =< 70 mm. C95 dB+ = dB+ stenderens og skinnens dimmensjon. 2/2 = 2 lag std gips på hver side, 2F/2F = 2 lag Brannplate type F på hver side. M45 = Min 45 mm mineralull, S95 = Min 95 mm fastholdt steinull med densitet 50 kg/m3
(1) Oppgitte lydverdier for feltet (R'w) Sintef Byggforsk sier: Ved normalt gode flanketransmisjonsforhold og god lufttetting, er feltmålte verdier 3-5 dB lavere enn laboratoriemålte verdier.
|